Navien fault codes, explained properly

Navien boilers use a three digit E code. They are less common in the North East than the big four, which means fewer engineers know them well. Here is what each one means.

Look up your code
E003, E012, E016, E030, E046, E109 and E517 in full
Including the scale related mixing valve fault
Fixed price diagnosis, no call out fee on top
Gas Safe registered across the North East
Navien boiler locked out on a fault code? Tell us the code and the model, no obligation. Call 0191 540 2051
16+
Years experience
£89
Fixed diagnosis fee
4.9★
Google rating
Same day
Attendance available

Reading a Navien fault code

Navien uses an E followed by three digits. They are a smaller presence in the North East than Worcester, Vaillant, Baxi and Ideal, which has a practical consequence worth knowing: fewer local engineers work on them regularly and parts are less likely to be on a van.

One Navien code is specific to this region in an interesting way. E517 is a mixing valve fault, and limescale is one of the causes. That matters more around Sunderland and Seaham, where the water is at the harder end of the Northumbrian range, than it does in Durham or Peterlee where it is soft.

The reset rule, and why it matters

Almost every fault code can be cleared with the reset button, and almost everyone presses it more than once. That is the single most expensive habit in domestic heating.

A lockout is the boiler protecting itself. Resetting it tells the appliance to try again. Once is reasonable, because genuine one off glitches do happen. Repeatedly resetting a boiler that is locking out on ignition means it is pumping gas into the combustion chamber and failing to light it, over and over. Repeatedly resetting an overheat lockout means asking it to fire again into a system that cannot carry the heat away. Both do real damage, and both turn a known price repair into a bigger one.

Reset once. If it locks out again, stop and get it looked at.

Navien codes in detail

E003, ignition failure

The boiler attempted ignition three times and never established a flame, so it has locked out.

Why it happens: Gas supply interrupted or restricted, a frozen condensate pipe, a worn electrode, or a failing ignition transformer.

What you can do: Check the gas is on and other gas appliances work. Thaw an external condensate pipe with warm water. Reset once.

What an engineer does: Tests working gas pressure at the appliance, checks the electrode and transformer, and reads the stored fault history rather than working from the current display alone.

E012, flame loss

A flame was established and then lost during operation, which is a different fault from failing to light at all.

Why it happens: Gas pressure dropping under load, a flue restriction, or a flame rod that has degraded.

What you can do: Reset once. If it recurs, stop and get it looked at properly.

What an engineer does: Carries out flue gas analysis at full rate and a working pressure test, which separates a supply issue from an appliance issue.

E016, overheat

The appliance has exceeded its safe operating temperature and shut down.

Why it happens: Heat is not being carried away. A circulation problem, a failed pump, sludge, or a partly blocked heat exchanger.

What you can do: Do not keep resetting. Check whether radiators heat at all and check the pressure.

What an engineer does: Measures the flow and return difference to establish whether water is moving, checks the system water, and assesses the heat exchanger. On a heavily sludged system the repair is a clean, not a part.

E030, exhaust thermistor fault

The sensor monitoring flue gas temperature is reading abnormally.

Why it happens: A failed sensor, a wiring fault, or genuinely high flue temperature caused by a scaled or blocked heat exchanger.

What you can do: Nothing safely.

What an engineer does: Tests the sensor against manufacturer figures, and importantly checks whether the flue temperature really is high, because that points at the heat exchanger rather than the sensor.

E046, pressure sensor fault

The water pressure sensor is giving readings the board does not accept.

Why it happens: A faulty sensor, air in the system, or genuinely low pressure that the gauge is not reflecting accurately.

What you can do: Check the pressure gauge. If it reads normally and the fault persists, the sensor is the likely culprit.

What an engineer does: Compares the sensor reading against an independent gauge, which immediately shows whether the sensor or the system is at fault.

E109, fan fault

The fan is not running correctly or the board is not receiving the expected speed signal.

Why it happens: A worn fan motor, wiring or connector fault, or a board issue.

What you can do: Nothing. The fan is inside a sealed chamber.

What an engineer does: Checks fan current and speed signal and inspects the flue for restriction before condemning the fan.

E517, mixing valve fault

The valve that blends hot water to the set temperature is not operating correctly.

Why it happens: A failed valve motor, a wiring fault, or limescale binding the valve. In moderately hard water areas such as Sunderland and Seaham, scale is a genuinely common cause.

What you can do: Note whether the hot water temperature is fluctuating, which helps.

What an engineer does: Tests the valve motor and travel, and checks for scale. If the area has harder water it is worth discussing a scale reducer on the incoming main at the same time.

Tell us the code and the model and we will tell you what it usually means. Get a call back now

What these repairs cost

Same approach as every other brand we work on. One fixed fee to attend and diagnose, one fixed price for the repair, agreed before anything is ordered.

The honest caveat on Navien is parts availability. Because they are less common here, a part occasionally has to be ordered rather than fitted from the van. Where that is the case we tell you the timescale at the visit rather than leaving you waiting on a call. Prices are published on our boiler repair cost page.

If E517 turns out to be scale related and you are in a harder water part of the region, it is worth reading what hard water does to a boiler around Sunderland before deciding what to do next.

Navien questions we get asked

Useful if you have one of the less common boilers in the region.

Do you actually work on Navien boilers? +
Yes. They are less common in the North East than the big four brands, so we are honest about parts: common items we carry, and anything more specific may need ordering. You get told the timescale at the visit rather than afterwards.
What does E517 mean and why does it matter where I live? +
It is a mixing valve fault, and one of the causes is limescale binding the valve. Sunderland and the Seaham side sit at the harder end of the regional water range, so scale is a more likely cause there than in Durham or Peterlee where the water is soft. That changes whether a scale reducer is worth fitting alongside the repair.
E016 keeps coming back. Why? +
Because an overheat is a symptom rather than a fault. Something is stopping heat leaving the boiler, usually poor circulation from a failed pump or a sludged system. Clearing the code without addressing circulation guarantees it returns.
Is it worth keeping a Navien or switching brand? +
If it is in good order and reasonably young, keep it. When it does come to replacement, we will be straight about the fact that Worcester, Vaillant, Baxi and Ideal are better supported locally, which affects how quickly a future repair can be done.
How many times can I reset it? +
Once. That applies to every brand. A boiler that locks out twice on the same code is telling you something is wrong, and continuing to reset an ignition or overheat lockout causes real damage.