ecoTEC and ecoFIT boilers show an F code when they stop. Here is what each one means, which ones you can act on yourself, and which ones should not be reset twice.

Look up your code
F22, F28, F29, F75, F27, F20, F62 and F83 in full
The difference between F28 and F29, which matters
Fixed price diagnosis, no call out fee on top
Gas Safe registered across Tyne and Wear and Durham
Vaillant boiler locked out on a fault code? Tell us the code and the model, no obligation. Call 0191 540 2051
16+
Years experience
£89
Fixed diagnosis fee
4.9★
Google rating
Same day
Attendance available

Reading a Vaillant F code

Vaillant uses an F followed by a number. The code is shown on the display and, on ecoTEC models, the fault history is stored on the board so an engineer can see what has been happening rather than relying on what the boiler is doing at that moment.

Two codes look similar and are not. F28 means the boiler never managed to light from cold. F29 means it lit and then lost the flame while running. The first usually points at ignition or supply, the second at something interrupting combustion mid cycle. Treating them as the same fault is how the wrong part gets fitted.

The reset rule, and why it matters

Almost every fault code can be cleared with the reset button, and almost everyone presses it more than once. That is the single most expensive habit in domestic heating.

A lockout is the boiler protecting itself. Resetting it tells the appliance to try again. Once is reasonable, because genuine one off glitches do happen. Repeatedly resetting a boiler that is locking out on ignition means it is pumping gas into the combustion chamber and failing to light it, over and over. Repeatedly resetting an overheat lockout means asking it to fire again into a system that cannot carry the heat away. Both do real damage, and both turn a known price repair into a bigger one.

Reset once. If it locks out again, stop and get it looked at.

Vaillant codes in detail

F22, low water pressure

The boiler has shut down because there is not enough water in the sealed system to run safely.

Why it happens: Water has either escaped or the expansion vessel has failed. A leak on pipework or a radiator valve, recently bled radiators, a pressure relief valve passing water outside, or a pressure sensor reading incorrectly.

What you can do: Repressurise to 1.0 to 1.5 bar using the filling loop, then note how long it holds. Days rather than months means there is a genuine fault to find.

What an engineer does: Checks the outside discharge pipe, tests the expansion vessel charge with the system drained down, and pressure tests to separate a leak from a vessel failure.

F28, ignition failure on startup

The boiler tried to light several times from cold and never established a flame, so it has locked out.

Why it happens: A frozen condensate pipe is the dominant cause between November and March. Otherwise: gas supply interrupted, a worn ignition electrode, a gas valve fault, or gas pressure too low at the appliance.

What you can do: Check the gas is on and other gas appliances work. Thaw an external condensate pipe with warm water, never boiling. Reset once only.

What an engineer does: Tests working gas pressure under load, which is the test that finds an undersized or partly blocked supply pipe. Checks the electrode, the ignition lead and the gas valve before condemning anything.

F29, flame lost during operation

The boiler lit correctly and then the flame went out while it was running. That is different from F28 and points somewhere different.

Why it happens: Something interrupting supply or combustion mid cycle. A recurring condensate blockage, a gas supply that drops under load, a flue restriction, or a gas valve that is not holding.

What you can do: Reset once. If it comes back, stop resetting, because a boiler repeatedly losing flame is a genuine combustion issue.

What an engineer does: Runs a flue gas analysis with the boiler at full rate, which shows combustion quality directly, and checks gas pressure while the appliance is working rather than idle.

F75, pump or pressure sensor fault

When the pump starts, the boiler expects to see a small change in pressure. It has not seen one, so it does not believe water is moving.

Why it happens: A seized or failed pump, a faulty pressure sensor, air trapped in the system, or sludge restricting circulation. F75 is the classic Vaillant code after a system has sat idle all summer.

What you can do: Check the pressure is correct first, because low pressure can bring this on. Beyond that it needs testing.

What an engineer does: Confirms whether the pump is actually turning, tests the sensor, and looks at the system water. If the water is black, the answer is a clean rather than a new pump, and fitting a pump into a dirty system just repeats the fault.

F27, flame detected when there should be none

The boiler is seeing a flame signal when the gas valve should be closed. This one is treated as urgent for good reason.

Why it happens: A faulty flame sensor, moisture on the control board, or a gas valve not sealing fully.

What you can do: Do not keep resetting this one. Turn the boiler off and call a Gas Safe engineer.

What an engineer does: Tests the gas valve for correct shut off and checks the flame sensing circuit and board for moisture damage. A valve that is not sealing is a safety matter, not a convenience one.

F20, overheat protection

The overheat thermostat has tripped because the appliance got hotter than it is allowed to.

Why it happens: Heat is not leaving the boiler fast enough. Pump failure, a blocked or sludged system, a stuck valve, or a failed overheat stat.

What you can do: Check whether radiators are getting hot at all, and check the pressure. Then leave it alone.

What an engineer does: Measures the temperature difference across flow and return, which immediately shows whether water is circulating, then works back to the cause rather than replacing the stat and hoping.

F62, gas valve shutoff delay

The board has measured the gas valve taking too long to close.

Why it happens: A worn or sticking gas valve, a wiring fault, or a board fault.

What you can do: Nothing safely. Anything involving a gas valve is engineer territory.

What an engineer does: Tests the valve response and the board output to establish which of the two is actually at fault, because replacing a gas valve unnecessarily is an expensive mistake.

F83, flow and return thermistor fault

The temperature sensors are not showing the change the boiler expects when it fires.

Why it happens: Often there is simply not enough water in the boiler, so nothing heats up as it should. Otherwise a failed thermistor or an air lock.

What you can do: Check the pressure gauge first, because a system that has emptied itself will produce this.

What an engineer does: Checks pressure and circulation before touching the sensors, then tests thermistor resistance against the manufacturer figures.

Tell us the code and the model and we will tell you what it usually means. Get a call back now

What these repairs cost

One fixed fee to attend and diagnose, then one fixed price for the repair, agreed before any part is ordered. Nothing runs on an hourly rate.

Thermistors and sensors are at the cheap end. Pumps and fans sit in the middle. Gas valves and control boards are the expensive ones, which is exactly why we test before replacing rather than working down a list. Our full price list is on the boiler repair cost page.

One thing worth knowing about F75 in particular: if the system water is black, fitting a new pump without cleaning the system will bring the same code back within months. That is a system cleaning job as much as a boiler one, and we will tell you when that is the case.

Vaillant questions we get asked

What people ring up about before we attend.

What is the difference between F28 and F29? +
F28 means the boiler never lit in the first place. F29 means it lit and then the flame went out during operation. They point at different things: F28 usually ignition, gas supply or a frozen condensate, F29 usually something interrupting combustion mid cycle such as a flue restriction or a supply dropping under load.
My ecoTEC keeps showing F75. Do I need a new pump? +
Not necessarily, and quite often not. F75 means the boiler did not detect a pressure change when the pump started. That can be a failed pump, but it can equally be a pressure sensor, trapped air, or sludge stopping circulation. If the system water is black, a new pump into a dirty system will fail again. We check the water before recommending the part.
Is F27 safe to reset? +
No, and this is the one code on the list we would ask you not to reset. F27 means the boiler is sensing a flame when the gas valve should be shut. Turn the boiler off and ring a Gas Safe engineer.
F22 keeps coming back after I top the pressure up. Why? +
Because topping up is not a repair. If the pressure will not hold, water is leaving the system or the expansion vessel has failed. Those are two different jobs at two different prices, and a proper diagnosis separates them quickly.
Which Vaillant models do you repair? +
ecoTEC plus, ecoTEC pro, ecoFIT pure and the older ecoMAX and Turbomax units. We carry common Vaillant parts on the van, so most repairs are done on the first visit.
Do you cover my area? +
We cover Tyne and Wear and County Durham, including Sunderland, Durham, Washington, Newcastle, Gateshead, Chester le Street, Houghton le Spring, Hetton le Hole, Seaham, Peterlee, South Shields and Stanley. Call 0191 540 2051 to confirm your postcode.

Vaillant showing a fault code?

Tell us the code and the model and we will have a chat about what it usually means before anyone comes out. £89 fixed price diagnosis, no obligation.

Get a call back now

Help

Emergency? Call us now.

Get a call back now