Radiators Not Getting Hot Upstairs: The Usual Causes

When the radiators upstairs stay cold while the ones downstairs are roasting, the usual causes are air trapped at the top of the system, low boiler pressure, a circulating pump that is struggling to push water up to the first floor, radiators that have never been balanced, or a system so full of sludge that the water cannot get round. The good news is that the first two you can check yourself in a few minutes. The rest need an engineer, but they are all fixable. Here is how to work out which one you have.

Start with the quick checks

Before anyone gets a spanner out, run through these:

  • Are the upstairs radiators actually on? Thermostatic radiator valves get knocked to zero by furniture, curtains and children. Turn every valve on the cold radiators fully open.
  • Is the boiler pressure right? Look at the gauge on the front of the boiler. If it is below 1 bar with the heating off, there may not be enough water in the system to reach the top floor. Top it up using the filling loop, following the instructions in the boiler manual, and see if the upstairs radiators come back.
  • Is it only the tops of the radiators that are cold? Cold at the top with warmth at the bottom is air. Cold at the bottom with warmth at the top is sludge. This one detail tells you a lot.

Cause one: air at the top of the system

Air rises, so it collects in the highest radiators in the house. If the upstairs radiators are cold at the top or gurgle when the heating comes on, bleed them. Our guide to bleeding a radiator shows how. Start with the upstairs radiators, then check the boiler pressure afterwards and top it up if it has dropped.

If you have to bleed the same radiators every couple of weeks, the air is coming from somewhere. That usually means a small leak letting air in, or corrosion inside the system creating gas. Either way, it is worth getting looked at rather than living with it.

Cause two: low pressure

On a combi or a sealed system, the water has to be under enough pressure to fill every radiator right to the top of the house. When the pressure drops, the top floor is the first to suffer. If topping it up fixes things but it keeps dropping again, read our guide on boiler pressure that keeps dropping. A pressure relief valve letting by or a small leak on a joint are the common culprits.

Cause three: the pump is not pushing hard enough

The circulating pump moves hot water round the system. As pumps age, or as they clog with debris, they lose the strength to lift water to the upstairs radiators against gravity. The signs are radiators that are lukewarm rather than cold, upstairs heating up eventually but very slowly, or a humming pump that is hot to the touch. A pump can sometimes be freed or turned up a speed setting. If it is worn out, it needs replacing, which is a routine job.

Cause four: the system has never been balanced

Hot water takes the easiest route. On an unbalanced system, the radiators nearest the boiler grab most of the flow and the ones furthest away, often upstairs at the far end of the house, get what is left. Balancing means slightly closing the lockshield valve on the radiators that heat up first, so more water is pushed on to the ones that heat up last. It is fiddly and takes a while, but it costs nothing but time, and a good engineer will do it at the end of any pump or boiler job.

Cause five: sludge

Over the years, the water in a heating system reacts with the steel inside the radiators and produces a black, oily sludge. It settles at the bottom of radiators and in the pipework, narrows the route the water can take and makes the pump work harder. In a badly sludged system, the upstairs radiators can end up cold simply because the water cannot get there in any quantity.

This is especially common in houses with microbore pipework, which has a much smaller bore and blocks far more easily. A lot of the houses around Washington were built with it, which is why we see so many slow and patchy heating systems there. Our boiler repair Washington page goes into what that means for local homes.

The fix for sludge is a proper clean. A power flush pushes cleaning chemicals and water through the system at speed to shift the deposits, and a magnetic filter fitted afterwards catches anything that comes loose later. If a radiator is so badly blocked that flushing will not clear it, replacing that one radiator is often cheaper than fighting it.

Cause six: a valve that is not opening

If your upstairs and downstairs are on separate zones, a zone valve that is stuck or a faulty actuator can leave one whole floor cold while the other is fine. On older systems with a cylinder, a diverter valve that has stuck part way can do something similar, sending the heat to the hot water instead of the radiators. These are diagnosed quickly by an engineer and are usually a straightforward part swap.

When to ring us

If bleeding, topping up the pressure and opening the valves have not fixed it, the problem is in the pump, the valves or the water in the system, and it is time to get an engineer to look. Ring 0191 540 2051 and tell us what you have already tried, because it helps us turn up with the right parts. Cold radiators on their own are not an emergency, but they are a sign the system is under strain, and it is far better to sort them in autumn than in the middle of a cold snap.

Frequently asked questions

Why are my upstairs radiators cold but the downstairs ones hot?

Most often it is air at the top of the system, low boiler pressure, or a pump that is not pushing water up to the first floor with enough force. Bleed the upstairs radiators and check the pressure gauge first. If that does not fix it, the pump, the valves or sludge in the system are the next things to check.

Do I need a power flush?

Only if the system is sludged. The signs are radiators cold at the bottom, black water when you bleed them, a noisy boiler and heating that takes ages to warm up. If the radiators are cold at the top and clean water comes out when you bleed them, you have air, not sludge, and a flush will not help.

Can I balance the radiators myself?

You can, with patience and a small spanner for the lockshield valves. Turn the heating on, note the order the radiators heat up, and partly close the lockshields on the fastest ones so more flow reaches the slowest. It takes a few rounds of adjusting to get right.

Get a Gas Safe engineer on it

A few quick questions and we will call you back, usually within the hour.